1.2.33. card28ΒΆ

------------------------------------------------------------------------------
C28 JET/PLUME SOLUTION CONTROL AND OUTPUT CONTROL PARAMETERS
*
*     ID:  ID COUNTER FOR JET/PLUME
*   NJEL:  MAXIMUM NUMBER OF ELEMENTS ALONG JET/PLUME LENGTH
*  NJPMX:  MAXIMUM NUMBER OF ITERATIONS
*  ISENT:  0 USE MAXIMUM OF SHEAR AND FORCED ENTRAINMENT
*          1 USE SUM OF SHEAR AND FORCED ENTRAINMENT
*  ISTJP:  0 STOP AT SPECIFIED NUMBER OF ELEMENTS
*          1 STOP WHEN CENTERLINE PENETRATES BOTTOM OR SURFACE
*          2 STOP WITH BOUNDARY PENETRATES BOTTOM OR SURFACE
*  NUDJP: FREQUENCY FOR UPDATING JET/PLUME (NUMBER OF TIME STEPS)
*   IOJP: 1 FOR FULL ASCII, 2 FOR COMPACT ASCII OUTPUT AT EACH UPDATE
*         3 FOR FULL AND COMPACT ASCII OUTPUT, 4 FOR BINARY OUTPUT
*   IPJP: NUMBER OF SPATIAL PRINT/SAVE POINT IN VERTICAL
*  ISDJP: 1 WRITE DIAGNOSTICS TO JPLOG__.OUT
*  IUPJP:   I INDEX OF UPSTREAM WITHDRAWAL CELL IF ICAL=2 
*  JUPJP:   J INDEX OF UPSTREAM WITHDRAWAL CELL IF ICAL=2 
*  KUPJP:   K INDEX OF UPSTREAM WITHDRAWAL CELL IF ICAL=2 
*  GRPID:   ID NUMBER OF BOUNDARY GROUP
*
C28      ID    NJEL   NJPMX   ISENT   ISTJP   NUDJP    IOJP    IPJP   ISDJP   IUPJP   JUPJP   KUPJP     GRPID ! ID