1.2.104. card81ΒΆ

------------------------------------------------------------------------------
C81 OUTPUT ACTIVATION AND SCALES FOR 3D FIELD OUTPUT
*
*  VARIABLE:     DUMMY VARIABLE ID (DO NOT CHANGE ORDER)
*  IS3(VARID): 1 TO ACTIVATE THIS VARIABLE
*  JS3(VARID): 0 FOR NO SCALING OF THIS VARIABLE
*              1 FOR AUTO SCALING OF THIS VARIABLE OVER RANGE 0<VAL<255
*                AUTO SCALES FOR EACH FRAME OUTPUT IN FILES OUT3D.DIA AND
*                ROUT3D.DIA  OUTPUT IN I4 FORMAT
*              2 FOR SCALING SPECIFIED IN NEXT TWO COLUMNS WITH OUTPUT
*                DEFINED OVER RANGE  0<VAL<255 AND WRITTEN IN I4 FORMAT
*              3 FOR MULTIPLIER SCALING BY MAX SCALE VALUE WITH OUTPUT
*                WRITTEN IN F7.2 FORMAT (IS3DO AND ISR3DO MUST BE 1)
*
C81 VARIABLE    IS3D    JS3D    SMAX    SMIN