C7 TIME-RELATED INTEGER PARAMETERS
*
* NTC: NUMBER OF REFERENCE TIME PERIODS IN RUN
* NTSPTC: NUMBER OF TIME STEPS PER REFERENCE TIME PERIOD
* NLTC: NUMBER OF LINEARIZED REFERENCE TIME PERIODS
* NLTC: NUMBER OF TRANSITION REF TIME PERIODS TO FULLY NONLINEAR
* NTCPP: NUMBER OF REFERENCE TIME PERIODS BETWEEN FULL PRINTED OUTPUT
* TO FILE EFDC.OUT
* NTSTBC: NUMBER OF TIME STEPS BETWEEN USING A TWO TIME LEVEL TRAPEZOIDAL
* CORRECTION TIME STEP, ** MASS BALANCE PRINT INTERVAL **
* NTCNB: NUMBER OF REFERENCE TIME PERIODS WITH NO BUOYANCY FORCING(NOT USED)
* NTCVB: NUMBER OF REF TIME PERIODS WITH VARIABLE BUOYANCY FORCING
* NTSMMT: NUMBER OF NUMBER OF TIME STEPS TO AVERAGE OVER TO OBTAIN
* MASS BALANCE RESIDUALS OR MEAN MASS TRANSPORT VARIABLES (e.g. WASP Linkage)
* NFLTMT: USE 1 (FOR RESEARCH PURPOSES)
* NDRYSTP: IF > 0 THEN NUMBER OF TIME STEPS BEFORE AN ISOLATED CELL WILL BE FORCED TO GO DRY
* EFDC+ WILL TRACK THE 'WASTED' WATER IN QDWASTE
* NRAMPUP: NUMBER OF INITIAL LOOPS TO HOLD TIMESTEP CONSTANT FOR DYNAMIC TIME-STEPPING
* NUPSTEP: MINIMUM NUMBER OF ITERATIONS FOR EACH TIME STEP WHEN GROWING DTDYN
*
C7 NTC NTSPTC NLTC NTTC NTCPP NTSTBC NTCNB NTCVB NTSMMT NFLTMT NDRYSTP NRAMPUP NUPSTEP